Symptom Tree Printable Version Vehicle speed is too low for adequate cooling with high engine load Reduce the engine load. Increase the engine (fan) rpm…
Category: M11 Industrial Operation and Maintenance Manual
Symptom Tree Printable Version Bulk oil supply is contaminated Check the bulk oil supply. Drain the oil and replace with noncontaminated oil. Replace the oil…
Symptom Tree Printable Version Bulk coolant supply is contaminated Check the bulk coolant supply. Drain the coolant and replace with noncontaminated coolant. Replace the coolant…
Symptom Tree Printable Version Verify the complaint If low power is relevant, refer to the Engine Power Output Low symptom tree. If acceleration is poor,…
Symptom Tree Printable Version Keyswitch circuit is malfunctioning Check the vehicle, equipment, or vessel keyswitch circuit. Refer to the OEM service manual. Engine is…
Symptom Tree Printable Version Keyswitch circuit is malfunctioning Check the vehicle, equipment, or vessel keyswitch circuit. Refer to a Cummins Authorized Repair Location. Tachometer…
M11 Industrial Operation and Maintenance – Engine Will Not Crank or Cranks Slowly (Electric Starter)
Symptom Tree Printable Version Battery cables or connections are loose, broken, or corroded (excessive resistance) Check the battery cables and connections. Engine-driven units are…
Symptom Tree Printable Version Air pressure is low in the air tanks Increase air pressure with an external air source. Refer to Procedure 012-021 (Air…
Symptom Tree Printable Version Electronic fault codes are active For instructions on how to read active fault codes, refer to Procedure 101-007 (Electronic Controlled Fuel…
Symptom Tree Printable Version Electronic fault codes are active For instructions on how to read active fault codes, refer to Procedure 101-007 (Electronic Controlled Fuel…