Symptom Tree t029
| Cause | Correction |
|---|
|
Fuel shutoff valve(s) closed (electronically controlled injection) |
Check the fuel shutoff valve and circuit. Refer to Procedures Procedures 019-049 and 019-050 in the Troubleshooting and Repair Manual for CELECT™ Plus Systems, Bulletin No. 3666130, or Section TF in the Troubleshooting and Repair Manaul for CELECT™ Systems, Bulletin No. 3666084. |
![]() |
|
Fuel shutoff valve(s) closed (mechanical fuel system) |
Use the manual opening knob. Check the shutoff valve and the electrical circuit. Refer to Procedure 005-043. Replace the shutoff valve if necessary. |
![]() |
|
Fuel inlet restriction |
Check for fuel inlet restriction. Refer to Procedure 006-020. |
![]() |
|
Fuel leak is causing fuel to drain back in the suction line |
Check for fuel drain back. Refer to Procedure 005-011. |
![]() |
|
Air in the fuel system |
Check for air in the fuel system. Refer to Procedure 006-003. |
![]() |
|
Fuel pump (gear or shaft) is not rotating |
Check the fuel pump for shaft rotation and fuel flow. Refer to Procedure 005-016. |
![]() |
|
In-line check valve(s) are installed backwards or have incorrect part number |
Inspect the check valve(s) for correct installation and part number. |
![]() |
|
Fuel pump gear pump check valve is stuck open |
Replace the check valve. Refer to Procedure 005-026. |
![]() |
|
Fuel pump pressure regulator is stuck |
Check the fuel pump pressure regulator. Refer to Procedure 005-060. |
![]() |
|
Injector o-rings are damaged or missing |
Remove and check the injectors. Replace the injector o-rings. Refer to Procedure 006-026. |