Battery Voltage – Out of Range Low
|
Overview
| CODE | REASON | EFFECT |
| Fault Code: 441 PID: FMI: LAMP: Red SRT: |
Battery Voltage – Out of Range Low. Battery voltage is less than the low threshold detected by the Centinel™ control module. |
The Centinel™ control module voltage supply approaching a level at which unpredictable operation will occur. |
|
Centinel™ Control Module |
![]() |
Circuit Description
The Centinel™ control module receives unswitched battery voltage from the starter for heavy-duty. For high-horsepower, the Centinel™
control module receives switched power from the fuel shutoff valve solenoid. There are two in-line 5-amp fuses in the Centinel™ control module heavy-duty harness to protect the Centinel™ control module. The high-horsepower has only one 5-amp fuse. The battery return wires in the engine harness are connected to the engine block ground.
Component Location
The location of the battery will vary with the OEM. Refer to the OEM manual for the battery location.
Shop Talk
This fault can be caused by loose or corroded battery connections.
Troubleshooting Steps
| STEPS | SPECIFICATIONS | |
|---|---|---|
| STEP 1. | Check the equipment battery system. | |
| STEP 1A. Inspect the battery cable connections. | No damaged connections | |
| STEP 1B. Check the battery voltage. | Heavy-duty: 9 to 32 VDCHigh-horsepower (12-VDC): 8.2 – 17.3 VDC High-horsepower (24-VDC): 15.5 – 30.3 VDC |
|
| STEP 1C. Check the Centinel™ control module battery voltage. | Heavy-duty: 9 to 32 VDCHigh-horsepower (12-VDC): 8.2 – 17.3 VDC High-horsepower (24-VDC): 15.5 – 30.3 VDC |
|
| STEP 3. | Clear the fault code. | |
| STEP 3A. Disable the fault code. | Fault Code 441 inactive | |
Guided Step 1 – Check the equipment battery system.
| Guided Step 1A – Inspect the battery cable connections. | ||
|---|---|---|
Conditions
Action
|
|
|
| OK | NOT OK | |
|
No damaged connections |
Repair or replace the damaged connections
Refer to the OEM service manual. |
|
| Guided Step 1B – Check the battery voltage. | ||
|---|---|---|
Conditions
Action
|
|
|
| OK | NOT OK | |
|
Heavy-duty: 9 – 32 VDC High-horsepower (12VDC): 8.2 – 17.3 VDC High-horsepower (24VDC): 15.5 – 30.3 VDC |
Replace the battery Refer to OEM service manual. |
|
| Guided Step 1C – Check the Centinel™ control module battery voltage. | |
|---|---|
Conditions
Action
Refer to the wiring diagram for connector pin identification. |
|
| OK | NOT OK |
|
Heavy-duty: 9 – 32 VDC High-horsepower (12VDC): 8.2 – 17.3 VDC High-horsepower (24VDC): 15.5 – 30.3 VDC |
Replace the Centinel™ wiring harness. Refer to Procedure 019-131. |
Guided Step 2 – Clear the fault code.
| Guided Step 2A – Disable the fault code. | ||
|---|---|---|
Conditions
Action
|
|
|
| OK | NOT OK | |
|
Fault Code 441 inactive |
Return to the troubleshooting step or contact your local Cummins Authorized Repair Location if all the steps have been completed and checked again. |
|