Symptom Tree t095-105
This is symptom tree t095-105
| Cause | Correction |
|---|
|
ICON™ lamp bulb is malfunctioning |
Verify the bulb is secure in the socket. Check the ICON™ lamp for voltage. Replace the bulb, if necessary. Refer to the OEM troubleshooting and repair manual for the procedure. |
![]() |
|
ICON™ lamp circuit is malfunctioning |
Check the ICON™ lamp circuit. Refer to the OEM troubleshooting and repair manual for the procedure. |
![]() |
|
Battery voltage supply to the electronic control module (ECM) has been lost |
Check the battery connections. Check the fuses and the unswitched battery supply circuit. Refer to Procedure 019-087. |
Last Modified: 11-Dec-2003
