Mechanical Gas Fuel System G5.9, G8.3 – FAULT CODE 477

Battery 2 Voltage Low – Data Valid but Below Normal Operating Range – Moderately Severe Level


Overview

Battery 2 Voltage Low – Data Valid but Below Normal Operating Range – Moderately Severe Level

CODE REASON EFFECT
Fault Code: 477
PID: P444
SPN: 1376
FMI: 1/18
LAMP: Warning
SRT: 

Battery 2 Voltage Low – Data Valid but Below Normal Operating Range – Moderately Severe Level.

ECM voltage supply approaching a level at which unpredictable operation will occur.

Isolated Battery Supply Circuit
SMALL | MEDIUM | LARGE

Circuit Description

The 12-VDC isolated battery circuit provides operating power to the ECM. This supply is used by the ECM to provide the pulse width modulated signal to the fuel control valve.

Component Location

100-002 for the component location.

Shop Talk

This fault is usually caused by loose or corroded connections, a blown fuse or a tripped circuit breaker.

Refer to Troubleshooting Fault Code t05-477

Last Modified:  15-Jul-2010